Simulation of Airflow Distribution of Parallel-Type Electrostatic Fabric Filter in Coal-fired Power Plant

Full Text (PDF, 3081KB), PP.33-42

Views: 0 Downloads: 0

Author(s)

Man-yin Hu 1,* Xiu-hong Wang 1 Jing Zhang 1 Li-juan Yan 1 Kai Che 1

1. Dept. of Environmental Science and Engineering, North China Electric Power University, Baoding City, China

* Corresponding author.

DOI: https://doi.org/10.5815/ijisa.2011.01.05

Received: 21 Jun. 2010 / Revised: 13 Sep. 2010 / Accepted: 1 Dec. 2010 / Published: 8 Feb. 2011

Index Terms

Electrostatic Fabric Filter, Airflow distribution, Opening rate, Numerical simulation

Abstract

This paper introduces the status of parallel-type Electrostatic Fabric Filter was researched, and the factors influencing collection efficiency were analyzed in this paper. Using software Gambit, which also meshed the calculating region, a three-dimensional structure model of the precipitator was established. And then the numerical simulation of the air distribution characteristic was carried on with the software of fluent 6.2, which sets the boundary conditions, standard k-ε 2-equation model and SIMPLE algorithm; Then draw the path line and contour chart of the cross-section, obtained the mean square deviation value, analyzed the airflow distribution situation and the reasons for why its uneven. By setting an appropriate opening rate for the airflow distribution plates and collection plates to improve the air distribution. The results show that the airflow distribution can be uniformed by improving the opening rate of the collection plates. The numerical simulation result is more reasonable and can be used as the reference of optimizing the structural design of Electrostatic Fabric Filter.

Cite This Paper

Man-yin Hu, Xiu-hong Wang, Jing Zhang, Li-juan Yan, Kai Che,"Simulation of Airflow Distribution of Parallel-Type Electrostatic Fabric Filter in Coal-fired Power Plant", International Journal of Intelligent Systems and Applications(IJISA), vol.3, no.1, pp.33-42, 2011. DOI: 10.5815/ijisa.2011.01.05

Reference

[1] Hu manyin, Zhao yi, Liu zhong, Dust removal technology [M], Beijing: Chemical Industry Press, 2006

[2] Liu lisn bo, Xu shisen,ect. Development and experimental study of airflow distribution of the hybrid particulate collector for coal-fired power plant, 2005

[3] Hu Manyin, Zhao Yi, Liu Zhong, Dust removal technology [M], Beijing: Chemical Industry Press, 2006

[4] Hu Manyin, Yu Jinxing, Sun Xijuan, Yang Yong, Numerical Simulation of Flow Filed in Outside Sack Dust Remover, 2006

[5] Hu manyin, Yu jinxing, Sun xijuan, Yang yong, Numerical Simulation of Flow Filed in Outside Sack Dust Remover, 2006