IJEME Vol. 2, No. 1, 8 Jan. 2012
Cover page and Table of Contents: PDF (size: 636KB)
Full Text (PDF, 636KB), PP.59-66
Views: 0 Downloads: 0
Data analysis, uncertainty, LabVIEW, waste ga
The concentration or composition of industrial waste gas is an important parameter in process industry. According to the required of an industrial waste gas monitor and control project a system of data analysis and display is designed based on LabVIEW. The system has 6 modules including error analysis, equal precision data processing, Non-precision data processing, uncertainty evaluation, least squares and regression analysis.
Running results indicated that this system is steady and rapidly. It can be used to deal the concentration or composition data accurately in real-time and can be display the result by graph or character. Remarkably the system is designed by LabVIEW, it is easy to modify, upgrade and to use as a subVI in other LabVIEW control system.
Lu Qirong,Huang Yuanyuan,Wang Tao,Sun Lin,"A Data Analysis and Evaluation System on LabVIEW", IJEME, vol.2, no.1, pp.59-66, 2012. DOI: 10.5815/ijeme.2012.01.10
[1] Xuedong Jin,Evaluation of measurement uncertainties of virtual instruments, Sringer-Verlag London,30 March 2005.
[2] JAYNES E. T, "Information theory and statistical mechanics," PhysicalReview , vol. 106 (4), pp. 620-630,1957
[3] Warnick, K. F., Weng Cho Chew, "Error analysis of the moment method," Antennas and Propagation Magazine, IEEE , Vol.46(6), pp.38-53 , Dec 2004.
[4] R.B.Streets, "Arbitrary Non-Mean-Square Error Criteria," IEEE Transaction on Automatic Control, pp.376-377, October 1963.
[5] M. Zakai, "General Error Criteria," IEEE Transactions on Information Theory, pp. 94-95, January 1964.
[6] Xing Li, Weiru Fang, Qi Tian , "Error criteria analysis and robust data fusion," IEEE International Conference, vol.4, pp.37-40, Apr 1994.
[7] Furness.R, "The cost of measurement uncertainty," PCIC Europe, pp.1-8 ,June 2008.