IJEM Vol. 2, No. 5, 5 Oct. 2012
Cover page and Table of Contents: PDF (size: 200KB)
Full Text (PDF, 200KB), PP.22-27
Views: 0 Downloads: 0
Micro-channel plate heat pipe, ANSYS, modeling, grid division
In this paper, a simulation of three kinds of micro-groove plate heat pipes- rectangular; trapezoidal and triangular, is conducted by thermal analysis software ANSYS. Through comparing with the focal point temperature value of the surfaces of micro-groove plate heat pipes, respectively being 30W; 40W; 50W, the result is obtained that trapezoidal plate heat piper has more excellent performance.
Liu Yi-Bing, Huang Zhi-Gang,"Transfer Characteristics of Three Kinds of Micro-groove Heat Pipes", IJEM, vol.2, no.5, pp.22-27, 2012. DOI: 10.5815/ijem.2012.05.04
[1] Liu Yi-Bing, electronic cooling technique [J], Electronics Process Technology, 2007,28 (5):286-289.
[2] Peterson GP, MaHB,Theoretical analysis of the maximum heat transport in triangular grooves:a study of idealized micro heat pipes[J],ASME Journal of Heat Transfer,1996,118:731-739.
[3] HopkinsR,Faghri A,Khrustalev D,Flat Miniature Heat Pipes with Micro Capollary Grooves[J], ASME Journal of Heat Transfer,1999,121:102-109.
[4] Fan-Chun Li, Qu Wei, Sun F., etc., three micro-groove structure of the flat heat pipe heat transfer experimental study [J],electronic devices, 2003,26 (4):357-360.
[5] Liu Yi-Bing, Liu Guohua, ANSYS thermal analysis of the key technologies and research [J], Chongqing Institute of Technology (Natural Science), 2008,10 (6):104-107.